CCV-MS1Portable veterinary anesthesia ventilator
  • CCV-MS1
Portable veterinary anesthesia ventilator
Portable veterinary anesthesia ventilator
Model:
CCV-MS1
Brand:
Concernmed
Price:
Inquiry
MOQ:
1
Ship From:
Guangzhou
Shipping:
Payment Method

Related Products

Model: CCO-G011B
Model: CCO-G012B
Model: CCO-G850
Model: CCO-G011
Model: CCO-G012
Model: CCO-MS2
Model: CCO-MS2T
Model: CCO-560B1
Model: CC560B1A
Model: CCO-560B2
Model: CC560B2A
Model: CC560B2B
  • Best Sallers
  • New Arrivals
  • Model: CCX-V200D
    Medical Hospital Veterinary Equipment 20kw 200mA High Frequency Digital Vet X Ray Machine
  • Model: CCX-560
    Pet Hospital Clinic Radiology Equipment New Model Handheld Portable Animal Medical X-ray Machine
  • Model: CCX-V320D
    32KW/320mA Veterinary Digital x-ray machine
  • Product detail
  • Shipping methods
  • Payment methods
Monitoring display: high-definition digital tube display
Monitoring parameters: tidal volume, respiratory rate, inspiratory ratio,
peak airway pressure
Breathing mode: IPPV, MAN
Respiratory rate: 2 times/minute to 99 times/minute
Respiration ratio: 1:85:1, continuously adjustable
Tidal volume: 0,501500mL (using a turbine-type flow sensor)
Minute ventilation volume: not less than 16L/min
Peak airway pressure: 09.9kPa
Safety performance:
Maximum safe pressure of anesthesia breathing system: 6kPaHigh pressure limit: When the airway pressure exceeds the upper limit
set value, the ventilator will automatically limit it to ensure that the
airway pressure cannot continue to rise, so as to ensure the safety of the
patient.
Insufficient gas source pressure alarm: when the oxygen supply
pressure is lower than 0.2MPa, there will be a high-priority sound alarm,
the duration is greater than 7 seconds, and the sound intensity is greater
than 60dB (A).
Airway pressure upper limit alarm: 2KPa ~ 6KPa, continuously
adjustable; when the airway pressure exceeds the preset value, there
will be a sound alarm and screen text display immediately, and the
inspiratory phase will be switched to the expiratory phase.
Airway pressure lower limit alarm: 0KPa~2KPa, continuously
adjustable; when the airway pressure is lower than the preset value, the
delay is 4s~15s (the alarm delay does not exceed 15s), there is a sound
alarm and screen text display.
Alarm mute: The alarm mute (except for the alarm of insufficient
oxygen supply) is not more than 120 seconds, and the device will
automatically restore the alarm function when the time comes.
Alarm recovery: After the alarm condition disappears, the alarm
device automatically stops the alarm.